Battery energy storage systems for manufacturing facilities can reduce billed peak demand, shift electricity purchases to lower-price periods and store surplus on-site solar generation. When the installation includes the required islanding and transfer equipment, storage can also support selected production loads during an outage. Its value depends on the plant load profile, tariff and electrical integration.

However, factory energy storage is not simply a matter of installing enough batteries to cover average electricity consumption. Production schedules, motor starting loads, continuous process requirements, power quality, and grid connection limits all influence the appropriate system design. This guide explains how industrial battery energy storage works in manufacturing environments, which applications offer measurable value, how to determine the required battery capacity, and what manufacturers should consider before selecting a system.

Why Manufacturing Facilities Need Battery Energy Storage Systems

Manufacturing facilities often have more complex electrical demand patterns than offices or commercial buildings. Industrial machinery can consume substantial power during startup, acceleration, heating, cooling, or intensive production periods. For example, a factory may operate several production lines continuously while air compressors, injection molding machines, industrial chillers, and ventilation equipment cycle according to production requirements.

When multiple machines operate simultaneously, electricity demand can rise significantly above the normal operating level. Battery energy storage allows factories to manage these fluctuations without relying entirely on immediate electricity purchases from the grid.

侧面-PCS+GUIZI.png

Common Electricity Challenges in Manufacturing Facilities

Manufacturing ChallengeOperational ImpactPotential Battery Storage Application
High Peak Electricity DemandDemand charges increase when multiple machines operate simultaneously.Battery discharge reduces grid demand during peak periods.
Time-of-Use Electricity PricingProduction during expensive electricity periods increases operating costs.Load shifting moves part of electricity purchasing into lower-cost hours.
Production-Related Power InterruptionsEquipment shutdowns can cause downtime, material losses, and restart expenses.Engineered battery backup supports selected critical manufacturing loads.
Limited Grid Connection CapacityAdding machinery may exceed the factory's contracted grid import capacity.Battery storage can temporarily supplement available grid power.
Unused Solar GenerationSolar electricity generated during low-demand periods may be exported.Battery storage shifts surplus solar energy into later production hours.
Frequent Production Load ChangesPower demand varies with machine operating cycles and production schedules.An EMS coordinates charging and discharging with factory demand.

The main advantage of an industrial battery energy storage system is the ability to separate the timing of electricity purchases from the timing of electricity consumption. For example, suppose a manufacturing plant normally operates at 1,200 kW but reaches 1,600 kW during periods of simultaneous equipment operation.

If the factory aims to keep grid demand below 1,300 kW, the battery must supply up to:

1,600 kW − 1,300 kW = 300 kW

If the required 300 kW reduction is constant for two hours, the required AC energy output is approximately:

300 kW × 2 hours = 600 kWh

The battery's installed nominal capacity must be higher after considering usable state-of-charge limits, conversion losses, and battery aging. This calculation illustrates why industrial battery storage design should begin with the actual production load profile.

How Battery Energy Storage Works in Factories

A factory battery energy storage system stores electricity in rechargeable battery cells and releases it when required by the facility. In a typical behind-the-meter installation, the battery system connects to the factory's electrical distribution network through power conversion and protection equipment. During low-demand or lower-price periods, electricity charges the battery. When manufacturing electricity demand increases, the battery discharges to supplement power from the grid.

The energy management system coordinates this process according to production demand, electricity tariffs, battery operating limits, and available renewable generation.

Core Components of Industrial Battery Energy Storage Systems

ComponentMain FunctionImportance for Manufacturing
Battery Cells and ModulesStore electrical energy.Determine battery capacity, chemistry, and cycling characteristics.
Battery Management System (BMS)Monitors voltage, current, temperature, and state of charge.Maintains battery operation within defined electrical and thermal limits.
Power Conversion System (PCS)Converts electricity between AC and DC.Controls the battery's charging and discharging power.
Energy Management System (EMS)Schedules battery charging and discharging.Coordinates battery operation with electricity tariffs and production schedules.
Thermal Management SystemControls battery operating temperature.Supports battery performance under changing industrial operating conditions.
Electrical Protection EquipmentProvides fault detection, electrical isolation, and protection coordination.Supports integration with the factory's existing electrical distribution system.
Fire Detection and Protection SystemsProvides detection, emergency response, and protective functions.Supports industrial installation safety requirements.

Understanding Battery Power Energy Capacity and Discharge Duration

Industrial energy storage buyers must distinguish between battery power and energy capacity. Power capacity (kW or MW) determines how much electricity the system can deliver at one time. Energy capacity (kWh or MWh) determines how much electricity the battery can store.

For example:

  • A 500 kW / 1,000 kWh system has a nominal energy-to-power ratio of two hours.

  • A 500 kW / 2,000 kWh system has a nominal energy-to-power ratio of four hours.

  • A 1,000 kW / 2,000 kWh system has a nominal energy-to-power ratio of two hours.

Actual discharge duration depends on usable battery capacity, state-of-charge limits, discharge efficiency, auxiliary energy consumption, temperature, and degradation. A four-hour nominal ratio does not automatically guarantee four hours of full AC output under all operating conditions.

Five Key Applications of Battery Energy Storage Systems for Manufacturing Facilities

Industrial Battery Storage for Peak Shaving

Peak shaving is one of the most direct applications of battery storage in manufacturing facilities. Many industrial electricity tariffs include a demand charge based on the highest measured electricity demand during a billing period. Even a relatively short production peak can affect the factory's monthly electricity expenses.

Consider a manufacturing plant with the following electricity demand:

  • Normal operating demand: 1,200 kW

  • Maximum demand during production peaks: 1,600 kW

  • Target maximum grid demand: 1,300 kW

  • Assumed industrial demand charge: $18/kW/month

The battery must reduce grid demand by:

1,600 − 1,300 = 300 kW

Monthly gross demand-charge savings:

300 kW × $18/kW = $5,400

If this reduction is achieved in all 12 billing months:

Annual gross demand-charge savings = $64,800

This is an illustrative calculation, not a measured project result. Actual savings depend on the utility's demand-charge rules, the duration and timing of factory demand peaks, and battery availability. Some industrial tariffs also include ratchet charges or separate demand measurements for different time periods. These rules should be included in the dispatch model.

Time of Use Energy Storage for Manufacturing Plants

Factories operating two or three shifts may consume substantial electricity during expensive tariff periods. Battery storage can reduce costs by charging when electricity is cheaper and discharging during higher-price periods.

Suppose a manufacturing facility operates under the following tariff:

  • Off-peak electricity price: $0.08/kWh

  • Peak electricity price: $0.22/kWh

  • Battery AC-to-AC round-trip efficiency: 85%

  • Daily battery electricity delivered: 1,000 kWh

Any efficiency used in an initial financial example is a modeling assumption. For equipment selection, use the proposed system efficiency at the agreed measurement boundary, including the treatment of PCS losses and auxiliary consumption.

To deliver 1,000 kWh, the system must purchase approximately:

1,000 ÷ 0.85 = 1,176.5 kWh

Charging electricity cost:

1,176.5 × $0.08 = $94.12

Avoided peak electricity purchase:

1,000 × $0.22 = $220

Gross daily energy arbitrage benefit = $125.88

For 300 operating days:

Annual gross benefit = approximately $37,765

This figure excludes battery degradation, maintenance, financing, and other operating expenses. The key consideration is whether the factory has enough low-price charging time and sufficient battery capacity to discharge during expensive production hours.

Solar Plus Storage Systems for Manufacturing Facilities

Factories frequently have large roofs suitable for photovoltaic installations. However, solar electricity generation may not match the timing of production demand. A factory operating evening or night shifts may have substantial electricity demand after solar generation has declined. Similarly, a factory that reduces production during weekends may generate more solar electricity than it can consume immediately. Battery storage helps shift this electricity to later production periods.

For example, suppose a factory generates 2,000 kWh of surplus solar electricity during a low-demand day.

At an assumed 85% AC-to-AC round-trip efficiency, the battery could deliver approximately:

2,000 kWh × 85% = 1,700 kWh

If the electricity purchase price during the later production period is $0.20/kWh, the gross avoided purchase value would be:

1,700 × $0.20 = $340

However, the incremental benefit must subtract the compensation that the factory would otherwise receive for exporting the electricity, along with battery-related costs.

For instance, if the alternative export payment were $0.05/kWh, the incremental daily value would be:

$340 − (2,000 × $0.05) = $240

This calculation assumes all surplus electricity can be stored and subsequently used. Actual benefits depend on the site's generation profile, battery availability, export regulations, and tariff structure.

Battery Backup for Critical Manufacturing Equipment

Power interruptions can have consequences beyond the immediate loss of electricity. Depending on the manufacturing process, an unexpected shutdown may result in rejected materials, unfinished products, equipment resets, process stabilization time, and delayed shipments. Battery storage can support selected critical loads if the installation is engineered for backup operation.

Potential critical loads include:

  • Industrial control systems and PLC equipment

  • Production monitoring and communication networks

  • Selected process pumps and cooling equipment

  • Critical instrumentation

  • Designated automation equipment

  • Essential facility safety and control systems

Consider a production facility with 150 kW of selected critical loads that must remain powered for two hours.

Required usable AC energy:

150 kW × 2 hours = 300 kWh

Assuming an 85% usable energy fraction and 94% discharge-path efficiency:

Required nominal battery capacity:

300 ÷ (0.85 × 0.94) = approximately 375 kWh

Additional reserves and end-of-life capacity allowances may increase this requirement. A standard grid-connected energy storage system does not automatically function as an uninterruptible power supply. Continuous or near-instantaneous backup requires suitable transfer equipment, islanding controls, inverter capability, and protection coordination. Sensitive manufacturing equipment may still require a dedicated UPS.

Battery Storage for Factory Grid Capacity Expansion

Manufacturers expanding production may need additional electricity capacity to operate new equipment. However, increasing grid connection capacity can involve transformer replacement, utility infrastructure upgrades, or lengthy approval processes. Battery storage may provide an alternative for short-duration demand increases.

For example:

  • Factory grid import limit: 2,000 kW

  • Existing production load: 1,700 kW

  • Additional production equipment demand: 500 kW

  • Total requested demand: 2,200 kW

A battery supplying 200 kW could keep grid import at the 2,000 kW limit while sufficient stored energy remains available.

If this demand occurs for 90 minutes:

200 kW × 1.5 hours = 300 kWh

However, battery storage cannot indefinitely replace grid infrastructure when the additional demand continues for long periods. The factory must also have sufficient time and available grid capacity to recharge the battery between high-demand events.

Which Manufacturing Industries Benefit from Industrial Battery Energy Storage

Different manufacturing processes create different opportunities for industrial energy storage. The suitability of a battery system depends on the production schedule, machinery characteristics, tariff structure, and required operating duration.

Manufacturing IndustryTypical Electrical LoadsPotential Energy Storage Benefits
Automotive ManufacturingRobotic assembly lines, welding equipment, compressors, and production machinery.Peak demand management, electricity cost optimization, and selected control-system backup.
Metal FabricationCNC machines, welding systems, electric furnaces, and industrial motors.Management of short demand peaks and selected load shifting.
Food and Beverage ProcessingRefrigeration, packaging lines, pumps, and processing equipment.Peak shaving, solar integration, and backup for designated refrigeration controls.
Textile ManufacturingSpinning machines, weaving equipment, drying systems, and HVAC.Time-of-use load shifting and electricity demand management.
Electronics ManufacturingAutomated production equipment, HVAC, cleanroom systems, and process controls.Energy cost optimization and engineered support for selected critical electrical loads.
Plastics ManufacturingInjection molding machines, extrusion lines, chillers, and compressors.Peak demand reduction and improved utilization of on-site solar generation.

For facilities with highly variable electrical loads, detailed interval data is particularly important. Some machines create short starting-current transients that require separate power-quality solutions or appropriate inverter capabilities. Battery energy capacity alone does not establish whether the system can support those events.

Planning storage around production requirements

Begin with at least a year of interval electricity data and identify the production processes behind the largest peaks. Separate the demand that can be shifted by scheduling from the demand that requires battery discharge. Include compressors, chillers, furnaces, welding equipment and other large loads where relevant to the plant. For each candidate system, check continuous AC power, usable energy at the required future capacity, motor-starting requirements and the available recharge window. Daily consumption is useful context, but the energy above the target import limit determines a peak-shaving requirement.

Model backup separately from routine energy management. Define the critical circuits, the acceptable interruption time and the minimum state of charge that must be reserved. A battery cabinet alone does not establish those functions. Before procurement, agree the connection point, outage work needed for installation and the interfaces between the battery, PCS, EMS and existing protection. This makes the proposal relevant to the actual plant instead of relying on a generic capacity range.

HiTHIUM Commercial and Industrial project references in Europe

The project references in HiTHIUM's C&I products and solutions catalogue include a containerized 8.36 MW/16.72 MWh installation in Hamburg, Germany, using SMA PCS for peak-valley electricity arbitrage. A 9 MW/18.79 MWh project in Romania is integrated with the customer's photovoltaic system to store surplus generation and support electricity arbitrage. The catalogue also describes a 1.75 MW/3.65 MWh cabinet installation in Baktalórántháza, Hungary, for industrial energy management. These references illustrate different project scales and integration arrangements. They do not establish a common payback period or annual saving for all manufacturing facilities.

For a plant evaluating similar applications, compare the reference project with its own voltage, operating schedule, peak duration and PCS requirements. Ask for project-specific operating evidence when assessing production continuity or investment returns.

Choosing HiTHIUM Battery Energy Storage Systems for Manufacturing Facilities

Industrial battery storage projects require equipment that can meet the factory's power demand, discharge duration, environmental conditions, and expansion requirements. HiTHIUM develops lithium iron phosphate (LFP) battery technology and energy storage products for commercial and industrial applications. Its commercial and industrial energy storage solutions can be evaluated for manufacturing applications such as peak-valley electricity management, on-site solar integration, and industrial power demand optimization.

HiTHIUM products for manufacturing storage

HiTHIUM productNominal battery energyPower conversion arrangementRelevant application
∞Block 125kW/261kWh261 kWhIntegrated AC/DC all-in-one configuration with 125 kW nominal AC powerModular demand management and solar storage
∞Block 418kWh418 kWh classDC battery cabinet with a separately matched PCSProjects using a coordinated battery and PCS solution
∞Power 1022kWh1022.72 kWhBattery cabinet matched with an external PCS; the catalogue describes a 250 kW solutionApproximately 1 MWh per battery cabinet for multi-hour storage

HiTHIUM can work with PCS manufacturers to provide a coordinated battery and power conversion solution. The final quotation should identify the battery, PCS model, EMS, switchgear, transformer where required, and commissioning scope. Nominal battery energy is not the same as usable AC energy, and the catalogue configuration must be matched to the local grid and operating requirements.

Liquid cooling and installation space

These products use LFP batteries with liquid cooling to manage cell temperatures during operation. Cooling capability and any power derating must be checked against the plant ambient conditions and duty cycle. The ∞Power 1022kWh battery cabinet occupies approximately 3.4 m². This is the battery cabinet footprint only. The complete installation also needs space for the external PCS, service access, safety clearances and any other site equipment. Explore the HiTHIUM C&I battery storage product range and commercial and industrial energy storage solutions when comparing configurations.

Safety and Electrical Integration for Manufacturing Battery Storage Systems

Industrial battery storage must be integrated with the factory's existing electrical infrastructure without compromising equipment protection or personnel safety. Unlike standalone electrical equipment, an energy storage system may both consume and supply power. This bidirectional operation requires appropriate protection coordination and control logic.

Industrial Battery Storage Safety Requirements

Battery storage safety depends on cell chemistry, thermal management, electrical protection, fire detection, system controls, and installation conditions. Lithium iron phosphate batteries are widely used in stationary storage applications because of their thermal characteristics and suitability for repeated charging and discharging.

However, LFP systems are not free from thermal runaway or fire risks.

Depending on project location and system architecture, relevant standards and codes may include:

  • IEC 62619: Safety requirements for secondary lithium cells and batteries used in industrial applications.

  • IEC 62933 Series: Requirements addressing electrical energy storage systems.

  • UL 9540: Safety standard for energy storage systems and equipment.

  • UL 9540A: Test method evaluating thermal runaway fire propagation characteristics.

  • NFPA 855: Standard for installation of stationary energy storage systems.

These references do not establish that every product holds every listed certification. Manufacturers should request documentation applying to the exact supplied model and configuration.

Power Quality and Manufacturing Equipment Compatibility

Industrial electrical networks may contain equipment that produces harmonics, rapid load changes, and substantial starting currents.

Before installation, engineers should evaluate:

  • Voltage compatibility

  • Transformer and switchgear ratings

  • Short-circuit protection

  • Harmonic distortion

  • Power factor requirements

  • Grounding and electrical isolation

  • PCS response characteristics

  • Coordination with existing UPS and generator equipment

Industrial battery storage should not be assumed to solve all power quality problems automatically. For applications involving voltage disturbances, motor-starting events, or sensitive automation equipment, the required inverter capabilities and protection arrangements must be explicitly specified.

Advanced Strategies to Improve Manufacturing Battery Energy Storage Performance

Coordinate Battery Dispatch with Production Schedules

Manufacturing electricity demand is strongly influenced by production planning. For example, a factory may have predictable periods when production lines start, large motors operate simultaneously, or industrial cooling systems reach their maximum demand. Integrating production schedules into the battery EMS can help reserve stored energy for these periods. This strategy can also reduce unnecessary battery cycling during periods when production demand is already low.

Use Forecast Based Energy Management

Fixed charging and discharging schedules may not respond adequately to changing production volumes, electricity tariffs, or solar generation. Advanced energy management systems can use load forecasts, tariff information, weather conditions, and battery state of charge to determine operating schedules. One approach is model predictive control (MPC), which repeatedly updates charging and discharging decisions as new information becomes available. For factories with variable production demand, forecast-based operation can improve the coordination of peak shaving, energy arbitrage, and reserve capacity.

Any performance improvement should be verified against a consistent operating baseline rather than assumed from the control technology alone.

Plan for Battery Degradation and Factory Expansion

Battery usable capacity gradually changes with cycling and calendar aging.

Important factors include:

  • Depth of discharge

  • Operating temperature

  • Charging and discharging rates

  • Time spent at high state of charge

  • Annual energy throughput

Manufacturers should evaluate whether the selected system can continue meeting required power and energy targets near the end of its intended operating life.

Future production expansion should also be considered.

New machinery, additional production shifts, process electrification, and increased cooling demand may change the factory's electricity requirements. Modular energy storage systems can provide expansion opportunities, but compatibility between existing and future equipment should be verified before procurement.

Measure Industrial Battery Storage Performance After Commissioning

After installation, factory operators should compare actual electricity savings against the original project model.

Useful performance indicators include:

  • Monthly grid demand reduction in kW

  • Electricity shifted between tariff periods in kWh

  • Battery charging and discharging energy

  • Measured round-trip efficiency

  • Annual electricity cost savings

  • Battery availability

  • Capacity retention and degradation trends

  • Maintenance and auxiliary energy consumption

Production volume, weather, electricity tariffs, and operating schedules should be considered when comparing performance across different periods. This helps distinguish battery-related benefits from changes caused by unrelated factory operations.

Frequently Asked Questions About Battery Energy Storage Systems for Manufacturing Facilities

What Size Battery Energy Storage System Does a Factory Need

The required size depends on maximum grid demand, the intended power reduction, discharge duration, and the factory's operating schedule. For example, supplying 500 kW for two hours requires 1,000 kWh of usable AC energy. Installed battery capacity must also account for conversion losses, usable state-of-charge limits, operating reserves, and degradation. A detailed analysis of at least 12 months of electricity demand data is recommended.

Can Industrial Battery Storage Reduce Manufacturing Electricity Costs

Yes. Battery storage can reduce manufacturing electricity expenses through peak shaving, time-of-use load shifting, and improved solar self-consumption. The financial benefit depends on the factory's demand charges, electricity price differences, operating patterns, and battery efficiency. Actual savings should be calculated using the facility's tariff and measured load profile.

Can a Battery Energy Storage System Keep Factory Production Running During a Power Outage

A properly engineered battery backup system can support selected manufacturing loads during an outage. However, continuous production depends on the required power, available energy capacity, inverter capability, transfer arrangements, and compatibility with the factory's equipment. Sensitive machinery may require a dedicated UPS, while long-duration production backup may require additional generation or energy storage capacity.

How Long Do Industrial Battery Energy Storage Systems Last

Battery lifetime depends on chemistry, operating temperature, depth of discharge, cycling frequency, and maintenance. Buyers should review the manufacturer's specified cycle-life conditions, calendar-life assumptions, guaranteed capacity retention, energy throughput, and warranty limitations. Project financial models should account for degradation throughout the intended operating period.

Can Battery Energy Storage Be Added to an Existing Manufacturing Facility

Many operating factories can be evaluated for battery storage retrofits. Installation feasibility depends on available space, electrical distribution capacity, transformer and switchgear compatibility, environmental conditions, safety requirements, and utility interconnection rules. A factory electrical assessment should determine the appropriate connection arrangement and whether equipment upgrades are necessary.

Selecting Battery Energy Storage Systems for Manufacturing Facilities with HiTHIUM

Battery energy storage systems for manufacturing facilities can help factories manage peak electricity demand, reduce energy purchases during expensive tariff periods, increase solar self-consumption, and support selected critical electrical loads. The most effective industrial energy storage projects begin with measurable production and electricity requirements. Power capacity, usable energy, discharge duration, round-trip efficiency, system safety, and lifecycle cost should determine the final design.

For manufacturers operating multiple shifts, expanding production capacity, or integrating on-site renewable generation, HiTHIUM provides commercial and industrial battery energy storage solutions based on LFP battery technology, liquid-cooled cabinets, and modular energy storage configurations. Its portfolio includes ∞Block 261kWh and 418kWh cabinets and the higher-capacity ∞Power 1022kWh system, providing options for different industrial energy storage requirements.

Before requesting a system proposal, prepare your factory's electricity tariff, 12-month load profile, production schedule, installation conditions, existing solar generation capacity, and expected energy storage objectives. Contact HiTHIUM to discuss your manufacturing facility's energy requirements, product specifications, and suitable industrial battery energy storage configurations.


OK
Subscription Success
Congratulations on your successful subscription to HiTHIUM news
Got it
Please leave your business requirements and our experts will contact you as soon as possible.
Pre-sale
After-sale
Media
Request Brochure
Get Quote
Full Name *
Email *
Phone *
You Are Interested In *
Cell
Module
Utility System
C&I System
Residential System
Region *
Afghanistan
Aland Islands
Albania
Algeria
American Samoa
Andorra
Angola
Anguilla
Antarctica
Antigua and Barbuda
Argentina
Armenia
Aruba
Australia
Austria
Azerbaijan
Bahamas
Bahrain
Bangladesh
Barbados
Belarus
Belgium
Belize
Benin
Bermuda
Bhutan
Bolivia
Bonaire, Sint Eustatius and Saba
Bosnia and Herzegovina
Botswana
Bouvet Island
Brazil
British Indian Ocean Territory
British Virgin Islands
Brunei Darussalam
Bulgaria
Burkina Faso
Burundi
Cabo Verde
Cambodia
Cameroon
Canada
Cayman Islands
Central African Republic
Chad
Chile
China
Christmas Island
Cocos (Keeling) Islands
Colombia
Comoros
Cook Islands
Costa Rica
Cote d'Ivoire
Croatia
Cuba
Curacao
Cyprus
Czech Republic
Democratic Republic of the Congo
Denmark
Djibouti
Dominica
Dominican Republic
Ecuador
Egypt
El Salvador
Equatorial Guinea
Eritrea
Estonia
Ethiopia
European Union
Falkland Islands
Faroe Islands
Federated States of Micronesia
Fiji
Finland
France
French Guiana
French Polynesia
French Southern Departments
Gabon
Gambia
Georgia
Germany
Ghana
Gibraltar
Greece
Greenland
Grenada
Guadeloupe
Guam
Guatemala
Guernsey
Guinea
Guinea-Bissau
Guyana
Haiti
Heard and McDonald Islands
Honduras
Hungary
Iceland
India
Indonesia
Iran
Iraq
Ireland
Isle of Man
Israel
Italy
Jamaica
Japan
Jersey
Jordan
Kazakhstan
Kenya
Kingdom of Eswatini
Kiribati
Kuwait
Kyrgyzstan
Laos
Latvia
Lebanon
Lesotho
Liberia
Libya
Liechtenstein
Lithuania
Luxembourg
Madagascar
Malawi
Malaysia
Maldives
Mali
Malta
Marshall Islands
Martinique
Mauritania
Mauritius
Mayotte
Mexico
Moldova
Monaco
Mongolia
Montenegro
Montserrat
Morocco
Mozambique
Myanmar
Namibia
NATO
Nauru
Nepal
Netherlands
New Caledonia
New Zealand
Nicaragua
Niger
Nigeria
Niue
Norfolk Island
North Korea
North Macedonia
Northern Mariana Islands
Norway
Oman
Orange
Pakistan
Palau
Panama
Papua New Guinea
Paraguay
Peru
Philippines
Pitcairn Islands Group
Poland
Portugal
Puerto Rico
Qatar
Republic of the Congo
Reunion
Romania
Russian Federation
Rwanda
Saint Barthelemy
Saint Helena
Saint Kitts and Nevis
Saint Lucia
Saint Martin
Saint Pierre and Miquelon
Saint Vincent and the Grenadines
Samoa
San Marino
Sao Tome and Principe
Saudi Arabia
Senegal
Serbia
Seychelles
Sierra Leone
Singapore
Sint Maarten (Dutch part)
Slovakia
Slovenia
Solomon Islands
Somalia
South Africa
South Georgia and the South Sandwich Islands
South Korea
South Sudan
Spain
Spitzbergen
Sri Lanka
State of Palestine
Sudan
Suriname
Sweden
Switzerland
Syria
Tajikistan
Tanzania
Thailand
Timor-Leste
Togo
Tokelau
Tonga
Trinidad and Tobago
Tunisia
Turkey
Turkmenistan
Turks and Caicos Islands
Tuvalu
Uganda
Ukraine
United Arab Emirates
United Kingdom
United Nations
United States Minor Outlying Islands
Uruguay
USA
Uzbekistan
Vanuatu
Vatican City
Venezuela
Vietnam
Virgin Islands of the United States
Wallis and Futuna Islands
Western Sahara
Yemen
Zambia
Zimbabwe
City *
Company *
Demand scale estimation *
MWh
Expected delivery time *
Specific requirements
Preffered Method of contact *
By Email
By Phone
Captcha *
I agree that HiTHIUM may send me regular newsletters and up to date information on HiTHIUM products and services, promotions and news via e-mail, post and/or telephone in accordance with the data protection declaration, l can withdraw my consent at any time.
Pre-sale
After-sale
Media
Full Name
Email *
Phone *
Company *
Project Address *
City
State/Province
Zip Code
Country *
Urgent Level *
Very Urgent
Urgent
Nomal
Product Model *
Cell
Module
System
General Inquiry
Under Warrany *
Yes
No
Date of Purchase
Date of Installation
When This Issue Occur *
How Can We Help You With *
Consultation
Complaints
Repair
Training and Guidance
Installation and Commissioning
Regular Inspections
Contractual Services
Details of the Issue *
Reference Image
Captcha *
I agree that HiTHIUM may send me regular newsletters and up to date information on HiTHIUM products and services, promotions and news via e-mail, post and/or telephone in accordance with the data protection declaration, l can withdraw my consent at any time.
You can also get in touch with our service team by sending email with your pre-filled request form.
check email address here
Pre-sale
After-sale
Media
Media Name *
Media Address *
Full Name *
Position *
Email *
Phone *
Purpose of the letter *
Interview
Activity
Visit
Advertising
Other
Detailed requirement description *
Captcha *
I agree that HiTHIUM may send me regular newsletters and up to date information on HiTHIUM products and services, promotions and news via e-mail, post and/or telephone in accordance with the data protection declaration, l can withdraw my consent at any time.